1)Communication: RS485/Modbus-Rtu
2)Multi-circuit: 30 circuit
3)Rated U and I: U:AC 220V/380V I:5A
·30 channels of current power, electric energy and other full power parameters
·1 RS485 communications

DIN 35mm
144*90*45







|
|
||
|
|
|
48VDC,240VDC,336VDC
|
|
|
±20 percent |
|
|
|
Instantaneous voltage 2 times per second
|
|
|
|
|
5V(Hall sensor, ±12V powered by AMC100-ZD)
|
|
|
Duration is 1.2 times, instantaneous 10 times/second
|
|
|
|
|
Less than or equal to 2500m
|
|
|
Operation:-15 degree -55 degree Storage:-25 degree -70 degree
|
|
|
|
Relative humidity Less than or equal to 93 percent
|
|
|
|
Method DIN35mm rail or bottom plate installation
|
|
|
|
Powered by AMC100-ZD; DC 12-24V power supply when used
|
|
|
|
The insulation resistance between all terminals and the conductive parts on the shell must be at least 100MΩ
|
|
|
|
RS485/Modbus-RTU
|
|
|
|
IP20 |
|
![]() |
AMC100-ZA |
Monitoring the full power parameters of the A plus B dual three-phase AC incoming circuit, 8 switching status inputs, 4 switching status outputs, 2 leakage monitoring, 1 temperature and humidity detection, 3 RS485 communications |
148 |
![]() |
AMC-FA30 |
Monitor the full power parameters of a total of 30 branches of A plus B dual AC outlets, and 1 RS485 communication |
133 |
![]() |
AMC-FA48 |
Monitor the full power parameters of a total of 48 branches of A plus B dual AC outlets, and 1 RS485 communication |
177 |
![]() |
AMC-FAK30 |
Monitor the full power parameters and switch status of a total of 30 branches of A plus B dual AC outlets, and 1 RS485 communication |
177 |
![]() |
AMC-FAK48 |
Monitor the full power parameters and switch status of a total of 48 branches of A plus B dual AC outlets, and 1 RS485 communication |
237 |
![]() |
AMC100-ZD |
Monitors the voltage, current, power, and electric energy of 2 independent incoming lines A plus B,8 switching input, 4 switching output , 1 temperature and humidity detection, and 3 RS485 communications |
148 |
![]() |
AMC100-FD30 |
Monitor the full power parameters of A plus B dual DC outgoing lines in A total of 30 branches, and 1 RS485 communication |
133 |
![]() |
AMC-FD48 |
Monitor the full power parameters of A plus B dual DC outgoing lines in A total of 48 branches, and 1 RS485 communication |
177 |
![]() |
AMC100-FDK30 |
Monitor the full power parameters and switching status(active) of A plus B dual DC outlet 30 branches,and 1 RS485 communication |
177 |
![]() |
AMC100-FDK48 |
Monitor the full power parameters and switching status(active) of A plus B dual DC outlet 48 branches, and 1 RS485 communication |
237 |
গরম ট্যাগ: amc100-fd30, China amc100-fd30 manufacturers, suppliers, factory